Analysis of refrigerant pipe pressure drop of a CO₂ air conditioning unit for vehicles

Link:
Autor/in:
Verlag/Körperschaft:
Hamburg University of Technology
Erscheinungsjahr:
2019
Medientyp:
Text
Schlagworte:
  • Air conditioning
  • Piping
  • Pressure drop
  • R744
  • 600: Technik
  • 600
Beschreibung:
  • This study investigates the pressure drop in refrigerant pipes of a CO₂ automotive air conditioning unit. A test rig to measure the pressure drop of arbitrarily shaped pipes is presented. As boundary conditions at the inlet of the test section, mass flow, pressure and enthalpy of the refrigerant are independently adjustable to values that cover the whole operating range of a CO₂ automotive air conditioning system for cars in the premium segment. Numerical analysis using CFD and a one-dimensional modelling tool is carried out. The pressure drop for the suction pipe reaches values of up to 500 mbar. CFD simulation predicts the pressure drop with an error of 25.7% for single-phase flow whereas the deviation using one-dimensional models is 46.5%. During two-phase flow the error increases to 55.8% with one-dimensional models and 42.4% using CFD.
Beziehungen:
DOI 10.1016/j.ijrefrig.2019.04.005
Lizenzen:
  • info:eu-repo/semantics/openAccess
  • https://creativecommons.org/licenses/by-nc-nd/4.0/
Quellsystem:
TUHH Open Research

Interne Metadaten
Quelldatensatz
oai:tore.tuhh.de:11420/3640