Cavity Cut-Out Studies of a 1.3 GHz Single-Cell Cavity after a failed Nitrogen Infusion Process

Link:
Autor/in:
Beteiligte Personen:
  • Michel, Peter
  • Arnold, André
  • Schaa, Volker RW
Verlag/Körperschaft:
JACoW Publishing
Erscheinungsjahr:
2019
Medientyp:
Text
Beschreibung:
  • R&D on the nitrogen infusion process at DESY produced at the beginning a series of 1.3 GHz single-cell cavities which have shown severe deterioration in the vertical cold test which was completely unexpected and could not be explained. To investigate the reason for the deterioration, one of those cavities was optically inspected and a T- and H-Map test was done in collaboration with HZB. Together with 2nd Sound data, regions of interests were identified and cut from the cavity. Subsequent surface analysis techniques (SEM/EDX, SIMS, PIXE, EBSD, DB-PAS, PALS, XPS) were applied in order to identify the reason for the deterioration. Especially the differences between hot and cold spots as well as quench spots identified by T-Mapping were investigated.
Lizenz:
  • info:eu-repo/semantics/openAccess
Quellsystem:
Forschungsinformationssystem der UHH

Interne Metadaten
Quelldatensatz
oai:www.edit.fis.uni-hamburg.de:publications/d9f90628-fecd-4107-a60d-609f2aea7938