Effects of high-energy particle showers on the embedded front-end electronics of an electromagnetic calorimeter for a future lepton collider

Link:
Autor/in:
Erscheinungsjahr:
2011
Medientyp:
Text
Schlagworte:
  • Calorimeters
  • Colliding beam accelerators
  • Hadronic showers
  • Detectors
  • High Energy Physics
  • Readout Systems
  • Calorimeters
  • Colliding beam accelerators
  • Hadronic showers
  • Detectors
  • High Energy Physics
  • Readout Systems
Beschreibung:
  • Application Specific Integrated Circuits, ASICs, similar to those envisaged for the readout electronics of the central calorimeters of detectors for a future lepton collider have been exposed to high-energy electromagnetic showers. A salient feature of these calorimeters is that the readout electronics will be embedded into the calorimeter layers. In this article it is shown that interactions of shower particles in the volume of the readout electronics do not alter the noise pattern of the ASICs. No signal at or above the MIP level has been observed during the exposure. The upper limit at the 95\% confidence level on the frequency of fake signals is smaller than 1 x 10(-5) for a noise threshold of about 60\% of a MIP. For ASICs with similar design to those which were tested, it can thus be largely excluded that the embedding of the electronics into the calorimeter layers compromises the performance of the calorimeters. (C) 2011 Elsevier B.V. All rights reserved.
Lizenz:
  • info:eu-repo/semantics/restrictedAccess
Quellsystem:
Forschungsinformationssystem der UHH

Interne Metadaten
Quelldatensatz
oai:www.edit.fis.uni-hamburg.de:publications/b63f71a6-2361-4962-bdba-460bbb652059