Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves

Link:
Autor/in:
Erscheinungsjahr:
2021
Medientyp:
Text
Beschreibung:
  • BACKGROUND: A small aortic annulus is associated with increased risk of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear.

    METHODS: Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multidetector computed tomography-derived annulus area < 400 mm2. TAVI was performed with a balloon-expanding intra-annular (Sapien-3, n = 288), self-expanding intra-annular (Portico, n = 110), self-expanding supra-annular (Evolut, n = 179 and Acurate-Neo, n = 428) and mechanically expanding infra-annular (Lotus, n = 64) THV according to local practice. PPM was defined as indexed effective orifice area ≤ 0.85cm2/m2.

    RESULTS: A small annulus was found in 1069 (12.7%) patients. PPM was detected in 38.3% overall with a higher prevalence after implantation of a balloon-expanding intra-annular or mechanically expanding infra-annular THV compared to self-expanding intra- and supra-annular THV. Multivariable analysis linked self-expanding THV (Evolut: Odds ratio [OR] 0.341, Acurate-Neo: OR 0.436, Portico: OR 0.291), postdilatation (OR 0.648) and age (OR 0.968) to lower rates of PPM, while aortic valve calcification was associated with an increased risk (OR 1.001). Paravalvular regurgitation > mild was more frequent after TAVI with self-expanding THV (p = 0.04).

    CONCLUSION: In this large contemporary multicenter patient population, a substantial number of patients with a small aortic anatomy were left with PPM after TAVI. Self-expanding supra- and intra-annular THV demonstrated superior hemodynamics in these patients at risk, however at the cost of higher rates of residual paravalvular regurgitation.

Lizenz:
  • info:eu-repo/semantics/openAccess
Quellsystem:
Forschungsinformationssystem des UKE

Interne Metadaten
Quelldatensatz
oai:pure.atira.dk:publications/dc354509-1706-4812-84c8-534f00fbf18e