Biomechanical evaluation of peri- and interprosthetic fractures of the femur.

Link:
Autor/in:
Erscheinungsjahr:
2010
Medientyp:
Text
Beschreibung:
  • BACKGROUND:: Because of an increasing life expectancy of patients and the rising number of joint replacements, peri- and interprosthetic femoral fractures are a common occurrence in most trauma centers. This study was designed to answer two primary questions. First, whether the fracture risk increases with two intramedullary implants in one femur; and second, whether a compression plate osteosynthesis is sufficient for stabilizing an interprosthetic fracture. METHODS:: Twenty-four human cadaveric femurs were harvested and four groups were matched based on the basis of bone density using a peripher quantitative computer tomography (pQCT). All groups-(I) hip prosthesis with a cemented femoral stem; (II) hip prosthesis and retrograde femoral nail; (III) hip prosthesis, retrograde femoral nail, and lateral compression plate; (IV) all three implants with an additional simulated interprosthetic fracture-were biomechanically tested in a four-point bending in lateral-medial direction. RESULTS:: The second group with two intramedullary implants exhibited 20% lower fracture strength in comparison with group 1 with proximal femoral stem only. The stabilization of an interprosthetic fracture with a lateral compression plate (group IV) resulted in a fracture strength similar to femur with prosthesis only. CONCLUSION:: Two intramedullary implants reduce the fracture strength significantly. If an interprosthetic fracture occurs, sufficient stability can be achieved by a lateral compression plate. Because two intramedullary implants in the femur may decrease the fracture strength, the treatment of supracondylar femoral fractures with a retrograde nail in cases with preexisting ipsilateral hip prosthesis should be reconsidered.
  • BACKGROUND:: Because of an increasing life expectancy of patients and the rising number of joint replacements, peri- and interprosthetic femoral fractures are a common occurrence in most trauma centers. This study was designed to answer two primary questions. First, whether the fracture risk increases with two intramedullary implants in one femur; and second, whether a compression plate osteosynthesis is sufficient for stabilizing an interprosthetic fracture. METHODS:: Twenty-four human cadaveric femurs were harvested and four groups were matched based on the basis of bone density using a peripher quantitative computer tomography (pQCT). All groups-(I) hip prosthesis with a cemented femoral stem; (II) hip prosthesis and retrograde femoral nail; (III) hip prosthesis, retrograde femoral nail, and lateral compression plate; (IV) all three implants with an additional simulated interprosthetic fracture-were biomechanically tested in a four-point bending in lateral-medial direction. RESULTS:: The second group with two intramedullary implants exhibited 20% lower fracture strength in comparison with group 1 with proximal femoral stem only. The stabilization of an interprosthetic fracture with a lateral compression plate (group IV) resulted in a fracture strength similar to femur with prosthesis only. CONCLUSION:: Two intramedullary implants reduce the fracture strength significantly. If an interprosthetic fracture occurs, sufficient stability can be achieved by a lateral compression plate. Because two intramedullary implants in the femur may decrease the fracture strength, the treatment of supracondylar femoral fractures with a retrograde nail in cases with preexisting ipsilateral hip prosthesis should be reconsidered.
Lizenz:
  • info:eu-repo/semantics/restrictedAccess
Quellsystem:
Forschungsinformationssystem des UKE

Interne Metadaten
Quelldatensatz
oai:pure.atira.dk:publications/d48aa390-001d-4f83-8924-7bb892a76e03